Supply
Supply voltage12…30 VDC
Current consumption no load  <= 500 mA
 <= 600 mA based on Ethernet
Measured at24 VDC
Integrated heating
EquipmentStandard
Measuring range, typically
on natural surfaces0.05…100 m
on reflective target plate0.5…500 m
Resolution  0.1 mm
Measuring accuracy, typically
± 1.0 mm bei 2 σLLB502-01111
± 3.0 mm bei 2 σLLB502-01213
Measurement time, typically
Single measurement0.05…4 s
Tracking mode0.004…4 s
Reproducibility  ± 0.3 mm (2 σ), LLB502-01111
 ± 0.7 mm (2 σ), LLB502-01213
Light source
Laser diodeRed light
Wave length λ620…690 nm
Laser protection class2
International safety standardIEC 60825-1
American safety standardFDA 21CFR 1040.10
American safety standardobserve "Laser-Notice No. 50"
Radiant power P<= 1 mW
Beam divergence0.16 x 0.6 mrad
Pulse duration0.2…0.8 x 10E-9 s
Laser dot Ø at 10, 50, 100 m7x3 mm, 28x13 mm, 55x30 mm
Measurand output/refresh rate  <= 250 Hz
Tracking-Mode output rate  <= 1 kHz
EtherCAT - Interface
EquipmentOptional interface
EtherNet/IP™ - Interface
EquipmentOptional interface
PROFINET IO - Interface
EquipmentOptional interface
SSI - Interface
EquipmentStandard interface
SSI-Clock inputRS-422; 2-wire
SSI-Data outputRS-422, 2-wire
SSI-Clock frequency83…1000 kHz
SSI-Mono time, typically25 µs
Output codeBinary, Gray
Number of data bits23, 24
Analog - Interface
EquipmentStandard interface
Resolution12 Bit D/A converter
Current output0…20 mA, 4…20 mA
Load resistance (I)<= 500 Ohm
Analog outputPosition
Accuracy± 0.1 %
Configuration interfaces
RS232Point to Point
Number of devices100
For service purposesUSB 2.0 Type Mini-B socket
RS422/RS485Master/Slave
Transmission rate
Specific value100 MBit/s
Specific valuebased on Ethernet
Parameter/Function, changeable  Output code
 Output format
 Number of data bits
 SSI-Parameter
 Interface parameter
Type of parametrization  programmable
Programming - Tool  TR-Soft: LLB-Utility
External inputs
Function inputexternal triggering
Type of parametrizationprogrammable
Logic level"0“ < +2V, "1“ = Supply
Number of inputs1
External outputs
Status outputDevice error
Output level<= 30 VDC, <= 150 mA
Type of parametrizationprogrammable
Number of outputs3
Output stagesOpen Source
Output stagesOpen Drain
Output stagesPush Pull
Function outputsLevel control
Mass, typically  0.35 kg
******************************  ******************************
Device variants
Optional connection coverLLB502-20700, Ethernet/IP
Optional connection coverLLB502-20800, PROFINET-IO
Optional connection coverLLB502-20900, EtherCAT
Notereplaces the existing cover
General environmental conditions 
Vibration  DIN EN 60068-2-6
Specific value<= 50 m/s²
Sine60…150 Hz
Shock  DIN EN 60068-2-27
Specific value<= 500 m/s²
Half sine11 ms
Immunity to disturbance  DIN EN 61000-6-2
Transient emissions  DIN EN 61000-6-3
Working temperature
Standard-40…+50 °C based on Ethernet
Standard-40…+60 °C
Storage temperature, dry  -40…+70 °C
Relative humidity  85 %, non condensing
Protection class  DIN EN 60529
StandardIP65