| Advanced data for product |
| Supply |
| Supply voltage | 24 VDC ± 10 % |
| Current consumption no load | <= 100 mA per measuring system |
| Measuring principle | magnetostrictive |
| Measuring length, standard | 50…2000 mm, in steps |
| Resolution | 0.04 mm (internal) |
| Linearity deviation | ± 0.10 mm <= 1500 mm |
| | ± 0.15 mm > 1500 mm |
| Reproducibility | 0.04 mm |
| Hysteresis | 0.02 mm <= 1500 mm |
| | 0.1 mm > 1500 mm |
| Characteristics - Validity | using original TR Magnets |
| Temperature coefficient | < 40 ppm/°C FS |
| FS: | Full-Scale |
| Straight line velocity | no restrictions |
| Mounting position | no restrictions |
| Material - Measuring body | Cr/Ni - alloy |
| Rod end mounting | Option |
| Magnet | T4-M33 |
| | other on request |
| Analog - Interface |
| Voltage/Current | Factory setting |
| Resolution | 16 Bit D/A converter |
| Voltage output | 0…+10 VDC |
| Load resistance (U) | >= 0.68 kOhm |
| Current output | 0…20 mA |
| Current output | 4…20 mA |
| Load resistance (I) | <= 500 Ohm |
| Cycle time internal, <= 0.80 m | 1.00 ms |
| Cycle time internal, <= 1.50 m | 2.00 ms |
| Cycle time internal, <= 2.50 m | 3.00 ms |
| Cycle time internal, > 2.50 m | 4.00 ms |
| External inputs |
| Set-Input 1 | Analog initial point |
| Set-Input 2 | Analog end point |
| Logic level | "0“ < +2V, "1“ = Supply |
| General environmental conditions |
| Vibration | DIN EN 60068-2-6 |
| Specific value | <= 100 m/s² |
| Sine | 50…2000 Hz |
| Shock | DIN EN 60068-2-27 |
| Specific value | <= 1000 m/s² |
| Half sine | 11 ms |
| Immunity to disturbance | DIN EN 61000-6-2 |
| Transient emissions | DIN EN 61000-6-3 |
| Working temperature |
| Standard | 0…+70 °C |
| Optional | -20…+70 °C; |
| Storage temperature, dry | -30…+85 °C |
| Relative humidity | 98 %, non condensing |
| Protection class |
| Standard | IP65 |
| Stray magnetic field | DIN EN 61000-4-8, Test Level 4 |
| Measuring reference | Measuring plane |
| Pressure resistance |
| Static | PN = 600 bar |