产品详情
拼接式 Splicing type

拼接式 Splicing type

编号:LMC55 326-  

规格:Profibus-DP/ProfiNet IO/CANopen

  • 电气参数
  • 机械参数
  • 资料下载
  • 认证证书
  • 配件资料
Advanced data for product
Supply
Supply voltage24 VDC, -20…+10 %
In case of UL / CSA approvalaccording to NEC Class 2
Current consumption no load
Master system< 80 mA
Single component< 90 mA
Measuring principle  magnetostrictive
Measuring length, standard  5…20 m, complete system
 2 m, Single component
 End component, variable
Resolution  0.05 mm
Linearity deviation  < 0.02 %
 ± 0.20 mm / Module
Reproducibility  0.05 mm
Hysteresis  0.1 mm
Characteristics - Validity  using original TR Magnets
Straight line velocity  no restrictions
Mounting position  no restrictions
Material - Measuring body  Aluminium extruded profile
Magnet  T1-S5520
 other on request
PROFINET IO - Interface
PROFINET IO – DeviceIEC 61158, IEC 61784-1
Physical LayerFast Ethernet, ISO/IEC 8802-3
PROFINET-SpecificationV2.3
Conformance ClassB, C
Real-Time-ClassesClass 1, 2 (RT), Class 3 (IRT)
Media Redundancy Protocol, MRPyes, is supported
PNO Encoder-ProfileClass 3 and 4, V4.2
Fast Start-Up (FSU)3-times faster start-up
Transmission rate
Specific value100 MBit/s
Cycle time  >= 1000 µs (IRT/RT)
Parameter/Function, changeable  Addressing
 Resolution
 Number of magnets
 Preset parameter
 Position averaging
 Counting direction
Type of parametrization  programmable
Programming - Tool  Fieldbus-Device
 TR-Soft: TRWinProg
Cycle time, internal  >= 2 ms
Optional Magnets
Number of magnets30
Magnet - Minimum distance100 mm
General environmental conditions 
Vibration  DIN EN 60068-2-6
Shock  DIN EN 60068-2-27
Immunity to disturbance  DIN EN 61000-6-2
Transient emissions  DIN EN 61000-6-3
Working temperature
Standard0…+70 °C
Optional-20…+70 °C;
differing from itsee UL specification
Storage temperature, dry  -30…+85 °C
Relative humidity  98 %, non condensing
Protection class
StandardIP65
Stray magnetic field  DIN EN 61000-4-8, Test Level 4
Measuring reference  Measuring plane

拼接式 Splicing type

×