产品详情
外置型 External type

外置型 External type

编号:LP46A 320-  

规格:ATEX Analog/ATEX ProfiNet/ATEX SSI

  • 电气参数
  • 机械参数
  • 资料下载
  • 认证证书
  • 配件资料
Advanced data for product
Nominal voltage
Specific value24 VDC
Power consumption  <= 3.5 W
Measuring principle  magnetostrictive
Measuring length, standard  50…3600 mm, in steps
Characteristics - Validity  using original TR Magnets
Straight line velocity  no restrictions
Mounting position  no restrictions
Material - Measuring body  Aluminium extruded profile
Magnet  Slider
 other on request
PROFINET IO - Interface  yes, other on request
SSI - Interface  yes, other on request
Analog - Interface  yes, other on request
General environmental conditions 
Specific value<= 100 m/s²
Sine50…2000 Hz
Shock
Specific value<= 1000 m/s²
Half sine11 ms
Immunity to disturbance  DIN EN 61000-6-2
Transient emissions  DIN EN 61000-6-3
Working temperature
Standard-20…+60 °C
Storage temperature, dry  -30…+85 °C
Relative humidity  98 %, non condensing
Protection class
StandardIP64
Stray magnetic field  DIN EN 61000-4-8, Test Level 4
Measuring reference  Measuring plane
Relev. Ex Directive/Standards
Directive 2014/34/EU (ATEX)Intended use
EN IEC 60079-0General requirements
EN/IEC 60079-14Installation, erection
EN 60079-15Equipment protection "n"
EN/IEC 60079-31Dust ignition protection “t”
DIN EN 60529Degrees of protection, IP code
EN 60079-7Equipment protection "e"
Ex protection - Data, Gas
Device group /-categoryII 3G (Gc, Zone 2)
Ignition protection typeec (increased safety)
Ignition protection typenAc (non-sparking equipment)
GroupIIC (Hydrogen)
GroupIIB (Ethylen)
Temperature, surfaceT5 (<= 100 °C)
Special conditionsyes (X), observe Ex manual
Ex protection - Data, Dust
Device group /-categoryII 3D (Dc, Zone 22)
Ignition protection typetc (Protection by enclosure)
GroupIIIC (conductive dust)
GroupIIIB (non conductive dust)
Temperature, surfaceT95°C
Special conditionsyes (X), observe Ex manual

外置型 External type

×