| Advanced data for product |
| Supply |
| Supply voltage | 9…36 VDC |
| Current consumption no load | <= 100 mA |
| Measuring principle | magnetostrictive |
| Measuring length, standard | 50…3000 mm |
| Linearity deviation | ± 0.04 % + 1 LSB |
| FS: | Full-Scale |
| Reproducibility | < 0.005 % FS, >= 50 µm |
| FS: | Full-Scale |
| Hysteresis | 0.1 mm |
| Characteristics - Validity | using original TR Magnets |
| Temperature coefficient | 100 ppm/°C FS |
| FS: | Full-Scale |
| Straight line velocity | no restrictions |
| Mounting position | no restrictions |
| Material - Measuring body | Cr/Ni - alloy |
| Magnet | T4-M33, T4-M22, T4-M20 |
| Analog - Interface |
| Voltage/Current | Factory setting |
| Resolution | 12 Bit D/A converter |
| Voltage output | 0…+10 VDC |
| Voltage output | +10…0 VDC |
| Current output | 4…20 mA |
| Current output | 20…4 mA |
| Load resistance (I) | 200 ... 500 Ohm |
| Parameter/Function, changeable | Analog Voltage/Current |
| | Counting direction |
| Type of parametrization | Factory setting |
| Cycle time internal, <= 2.00 m | 2.00 ms |
| Cycle time internal, <= 3.00 m | 3.00 ms |
| External inputs |
| F/R | Count direction |
| Logic level | "0“ < +2V, "1“ = Supply |
| General environmental conditions |
| Vibration | DIN EN 60068-2-6 |
| Specific value | <= 100 m/s² |
| Sine | 50…2000 Hz |
| Shock | DIN EN 60068-2-27 |
| Specific value | <= 1000 m/s² |
| Half sine | 11 ms |
| Immunity to disturbance | DIN EN 61000-6-2 |
| Transient emissions | DIN EN 61000-6-3 |
| Working temperature |
| Standard | -40…+85 °C |
| Storage temperature, dry | -40…+100 °C |
| Relative humidity | 90 %, non condensing |
| Protection class |
| Standard | IP65 |
| Optional | IP69K |
| Stray magnetic field | DIN EN 61000-4-8, Test Level 4 |
| Measuring reference | Measuring plane |
| Pressure resistance |
| Static | PN = 450 bar |
| Peak | Pmax = 750 bar |