| Advanced data for product |
| Supply |
| Supply voltage | 24 VDC, -20…+10 % |
| Current consumption no load | <= 100 mA |
| Measuring principle | magnetostrictive |
| Measuring length, standard | 50…3000 mm |
| Resolution | 0.01 mm |
| Linearity deviation | <= ± 0.015 % FS (min ± 50 µm) |
| Reproducibility | <= ± 0.005 % FS (min ± 10 µm) |
| Characteristics - Validity | using original TR Magnets |
| Straight line velocity | no restrictions |
| Mounting position | no restrictions |
| Material - Measuring body | Cr/Ni - alloy |
| Rod end mounting | Option |
| Magnet | T1-M17.4 |
| | T4-M33, Standard |
| | other on request |
| CANopen - Interface |
| CANopen | EN 50325-4 (CiA DS301) |
| Bus connection | ISO 11898-1, ISO 11898-2 |
| CAN Specification 2.0 A | 11-Bit Identifier |
| Device-Profile for Encoder | CiA DS406 |
| Layer Setting Services, LSS | CiA DS305 |
| Layer Management Services, LMT | CiA DS205-1, DS205-2 |
| Transmission rate |
| Specific value | 10, 20, 50, 100, 125, 250, 500 |
| Specific value | 800, 1000 kbit/s |
| Specific value | Default: 500 kbit/s |
| Adjustability | via LSS service, LMT service |
| Parameter/Function, changeable | Resolution |
| | Node-ID |
| | Preset parameter |
| | Transmission rate |
| | Counting direction |
| | Velocity parameter |
| Type of parametrization | programmable |
| Programming - Tool | Fieldbus-Device |
| Cycle time internal, <= 1.00 m | 0.50 ms |
| Cycle time internal, <= 1.50 m | 0.75 ms |
| Cycle time internal, <= 2.00 m | 1.00 ms |
| Cycle time internal, <= 3.00 m | 1.50 ms |
| Optional Magnets |
| Number of magnets | 3 |
| Magnet - Minimum distance | 80 mm |
| General environmental conditions |
| Vibration | DIN EN 60068-2-6 |
| Specific value | <= 100 m/s² |
| Sine | 50…2000 Hz |
| Sine | Resonance frequencies excluded |
| Shock | DIN EN 60068-2-27 |
| Specific value | <= 1000 m/s² |
| Half sine | 11 ms |
| Immunity to disturbance | DIN EN 61000-6-2 |
| Transient emissions | DIN EN 61000-6-3 |
| Working temperature |
| Standard | -40…+80 °C |
| differing from it | Use under UL cond.: +75°C |
| Storage temperature, dry | -40…+85 °C |
| Relative humidity | 98 %, non condensing |
| Protection class |
| Standard | IP67 |
| Pressure resistance |
| Static | PN = 400 bar |
| Peak | Pmax = 450 bar |