| Advanced data for product |
| Nominal voltage |
| Specific value | 24 VDC |
| Limit values, min/max | 11/27 VDC |
| Nominal current, typically |
| Specific value | 40 mA |
| Condition | unloaded |
| Supply |
| Optional | 5 VDC ± 5 % |
| Signal form | Square |
| Incremental signals, square |
| Channels | K1+, K1-, K2+, K2- |
| Phase position, electrically | 90 ° |
| Zero pulse, square |
| Channel (Channels) | K0+, K0- |
| Number of revolutions | 1x |
| Impulses, square wave | 8 |
| | 10 |
| | 16 |
| | 20 |
| | 25 |
| | 32 |
| | 40 |
| | 50 |
| | 64 |
| | 80 |
| | 100 |
| | 125 |
| | 128 |
| | 200 |
| | 250 |
| | 256 |
| | 400 |
| | 500 |
| | 512 |
| | 1024 |
| | 2048 |
| Accuracy | ± 0,7 ° |
| Output driver, TTL |
| Output level | RS-422, 5 VDC |
| Output frequency | <= 150 kHz |
| Output driver, HTL |
| Output level | Push-Pull, supply voltage |
| Output frequency | <= 150 kHz |
| Type of parametrization | Factory setting |
| Circular runout | 0.2 mm |
| Mass, typically | 0.15 kg |
| General environmental conditions |
| Vibration |
| Specific value | <= 100 m/s² |
| Sine | 50…2000 Hz |
| Shock |
| Specific value | <= 1000 m/s² |
| Half sine | 11 ms |
| Immunity to disturbance | DIN EN 61000-6-2 |
| Transient emissions | DIN EN 61000-6-3 |
| Working temperature |
| Standard | -25…+70 °C |
| Optional | -40…+70 °C; |
| Storage temperature, dry | -20…+85 °C |
| Relative humidity | 98 % |
| Protection class |
| Standard | IP65 |
| Optional | IP69K |