| Advanced data for product |
| Nominal voltage |
| Specific value | 24 VDC |
| Limit values, min/max | 11/27 VDC |
| Nominal current, typically |
| Specific value | 100 mA |
| Condition | unloaded |
| Supply |
| Optional | 5 VDC ± 5 % |
| Signal form | Square |
| Optional signal | Sine, 160 kHz (-3dB), U/I |
| Incremental signals, square |
| Channels | K1+, K2+ |
| inverted Channels | K1-, K2-, optional |
| Phase position, electrically | 90 ° |
| Zero pulse, square |
| Channel (Channels) | K0+ |
| inverted Channel | K0- optional |
| Number of revolutions | 1x |
| Length, electrically | 90 °, 180 °, 360 ° |
| Impulses, square wave | 9000 |
| | 10000 |
| | 18000 |
| Accuracy | ± 7" 18000 sine |
| | ± 5" square |
| | ± 5" 9000/10000 sine |
| Interpolation, optional | 2-on-1…50-on-1 subdivision |
| Output driver, TTL |
| Output level | RS-422, 5 VDC |
| Load current | <= 20 mA |
| Output frequency | <= 1 MHz |
| Output driver, HTL |
| Short-circuit proof | yes |
| Output level | Push-Pull, supply voltage |
| Load current | <= 20 mA |
| Output frequency | <= 300 kHz |
| Type of parametrization | Factory setting |
| Maximum Speed, mechanically | <= 4000 1/min |
| Shaft load, axial/radial | Own mass |
| Circular runout | ± 0.05 mm |
| Mass, typically | 0.5 kg |
| General environmental conditions |
| Vibration |
| Specific value | <= 100 m/s² |
| Sine | 20…2000 Hz |
| Shock |
| Specific value | <= 1000 m/s² |
| Half sine | 11 ms |
| Immunity to disturbance | DIN EN 61000-6-2 |
| Transient emissions | DIN EN 61000-6-3 |
| Working temperature |
| Standard | 0…+80 °C |
| Storage temperature, dry | -30…+80 °C |
| Relative humidity | 98 %, non condensing |
| Protection class |
| Standard | IP64 |
| Note | depending on connector type |