产品详情
安全防爆 Safety Atex

安全防爆 Safety Atex

编号:

ADV582M


规格:

ProfiNet + FS3/Profibus + FS/其他接口(详询工程师)

  • 电气参数
  • 机械参数
  • 资料下载
  • 认证证书
  • 配件资料
Advanced data for product
Nominal voltage
Specific value24 VDC
Limit values, min/max10/30 VDC
Nominal current, typically
Specific value110 mA
Specific value130 mA with second interface
Conditionunloaded
Supply
SELV/PELVIEC 60364-4-41
In case of UL / CSA approvalaccording to NEC Class 2
Protection class IIIDIN EN 61140
Polarity protection  yes
Short circuit protection  yes
 internal 1 A fuse
Overvoltage protection  yes, up to <= 60 V DC
Power consumption  <= 3 W
Device design
TypeMulti-Turn
Redundant scanning systemyes, double
Designmagnetic/magnetic
Total resolution  <= 29 Bit
Number of steps per revolution  <= 8192 = 13 bit resolution
Number of revolutions  <= 65536
Accuracy (functional)  ± 0.2 °
Reproducibility  ± 0.1 °
PROFINET IO - Interface
PROFINET IO – DeviceIEC 61158, IEC 61784-1
Physical LayerFast Ethernet, ISO/IEC 8802-3
PROFINET-SpecificationV2.3
Conformance ClassB, C
Real-Time-ClassesClass 1, 2 (RT), Class 3 (IRT)
PROFIsafe-ProfileNo. 3.192b
PROFIsafe-ProfilePROFIsafe V2.4 (BP)
PROFIsafe-ProfilePROFIsafe V2.6.1 (XP)
Media Redundancy Protocol, MRP
yes, is supported

PNO Encoder-ProfileClass 3 and 4, V4.2
Fast Start-Up (FSU)3-times faster start-up
SSI - Interface
EquipmentOptional interface
SSI-Clock inputRS-422; 2-wire
SSI-Data outputRS-422, 2-wire
SSI-Clock frequency<= 1MHz
SSI-Mono time, typically15 µs, 20 µs, 50 µs, 500 µs
Protocol, TR-specificFunction information + CRC
Output codeBinary, Gray
Number of data bits8…29
Type of parametrizationprogrammable
MTTFd, SSI150 a
SSI-Refresh time500 µs, asynchronous
Incremental - Interface
EquipmentOptional interface
Signal formSquare wave
Signal form, alternativeSIN / COS
Incremental signals, squareK1± K2±
Incremental signals, SIN/COSSIN± COS±, 1 Vss
Impulses, square wave1024…5120, in steps of 1024
Impulses, SIN/COS1024 ∼
Output driver, TTLRS-422, 5 VDC
Output driver, HTLPush-Pull, Supply Voltage
Type of parametrizationprogrammable
MTTFd, square180 a
MTTFd, SIN/COS190 a
Duty factor, square50 %, ± <= 10 %
Phase angle, square90 °, ± <= 20 ° (electr.)
Transmission rate
Specific value100 MBit/s
Cycle time  >= 1000 µs (IRT/RT)
Not safety related0.5 ms
Safety related3.0 ms
Preset writing cycles  >= 16 000 000
Speed output  safety-related
Resolution16/32 Bit
Accuracy (output value)± 3.6 1/min (magn./magn.)
Tracking errorsee Safety Manual
Parameter/Function, changeable  Integration time
 Preset parameter
 Scaling parameter
 Monitoring window
 Counting direction
 Velocity parameter
Type of parametrization  programmable
Programming - Tool  Fieldbus-Device
 TCI Device Tool
Functional safety
Safety principleRedundance with cross compare
SIL-StandardizationDIN EN 61508 / DIN EN 62061
SIL-StandardizationDIN EN 61800-5-2
SIL-LevelSIL2 / SIL CL 2
SIL-LevelSIL3 / SIL CL 3
PL-StandardizationDIN EN ISO 13849
Performance-Level (PL)PLe / Cat. 4
Performance-Level (PL)PLd / Cat. 3
Service life20 Years
PFH / PFH [D]SIL3, PLe: 1.00E-9 1/h
PFH / PFH [D]SIL2, PLd: 2.00E-8 1/h
PFH / PFH [D]PFH: DIN EN 61508-4
PFH / PFH [D]PFH [D]: DIN EN ISO 13849-1
PFDav, T = 20 aSIL3, PLe: 8.50E-5
PFDav, T = 20 aSIL2, PLd: 1.27E-3
MTTFd170 a, high
DCavgSIL2, PLd: 90 %
DCavgSIL3, PLe: 98 %, high/middle
ModeHigh demand, continuous
Proof-Test-IntervalT1 = 20 Years
Accuracy (safety)± 0.5 °
Safety functions
DIN EN 61800-5-2SLP (safely-limited position)
DIN EN 61800-5-2SDI (safe direction)
DIN EN 61800-5-2SCA (safe cam)
DIN EN 61800-5-2SS1 (safe stop 1)
DIN EN 61800-5-2SS2 (safe stop 2)
DIN EN 61800-5-2SOS (safe operating stop)
DIN EN 61800-5-2SLS (safely-limited speed)
DIN EN 61800-5-2SSR (safe speed range)
DIN EN 61800-5-2SSM (safe speed monitor)
Internal process safety time
Profisafe instances: , Times:2, DAT <= 14 ms, WCDT <= 7 ms
Profisafe instances: , Times:4, DAT <= 18 ms, WCDT <= 8 ms
Maximum Speed, mechanically  <= 5000 1/min
Shaft load, axial/radial  <= 50 N, <= 100 N
Bearing life time  >= 3.9E+10 revolutions
Bearing life time - Parameter
Speed3000 1/min
Operating temperature60 °C
Shaft load, axial/radial= 60 %
Degree of contaminationnormal
Mounting positionShaft horizontal
Point of origin, shaft load  Mounting flange + 10 mm
Shaft type
Shaft diameter [mm]10
Shaft diameter [mm]12
Shaft diameter [mm]14
Shaft formingParallel key/Groove
Angular acceleration  <= 10E+4 rad/s²
Moment of inertia, worst-case  <= 5.3E-6 kg m²
 at shaft diameter 14 mm
 depending from shaft forming
Start-up torque, worst-case  <= 3.4 Ncm (IP65,-20 °C,+6 σ)
 <= 10 Ncm (IP67,-20 °C,+6 σ)
 at shaft diameter 14 mm
 depending from shaft forming
Mass, typically  0.3…0.5 kg
Isolation voltage  500 V
General environmental conditions
Vibration  DIN EN 60068-2-6
Specific value<= 100 m/s²
Sine50…2000 Hz
Shock  DIN EN 60068-2-27
Specific value<= 1000 m/s²
Half sine11 ms
Immunity to disturbance  DIN EN 61000-6-2
Transient emissions  DIN EN 61000-6-3
Magnetic fields  DIN EN 61000-4-8
Specific value30 A/m
CriteriaA
Spatial directionX, Y, Z
Working temperature
Standard-20…+60 °C
Storage temperature, dry  -40…+90 °C
Relative humidity  98 %, non condensing
Protection class
StandardIP64
Noteobserve Ex User manual
Optionalextended to IP67
Installation height  <= 5000 m, above sea level
Resistance
against salt (seawater)DIN EN IEC 60068-2-52
Test methodTest method 1
excluded areAttachment parts
Relev. Ex Directive/Standards
Directive 2014/34/EU (ATEX)Intended use
EN IEC 60079-0General requirements
EN/IEC 60079-14Installation, erection
EN/IEC 60079-31Dust ignition protection “t”
DIN EN 60529Degrees of protection, IP code
EN 60079-7Equipment protection "e"
Ex protection - Data, Gas
Device group /-categoryII 3G (Gc, Zone 2)
Ignition protection typeec (increased safety)
GroupIIC (Hydrogen)
Temperature, surfaceT4 (<= 135 °C)
Temperature, surfaceT5 (<= 100 °C)
Temperature, surfaceT6 (<= 85 °C)
Special conditionsyes (X), observe Ex manual
Equipment protection levelGc (Zone 2)
Ex protection - Data, Dust
Device group /-categoryII 3D (Dc, Zone 22)
Ignition protection typetc (Protection by enclosure)
GroupIIIC (conductive dust)
GroupIIIB (non conductive dust)
Temperature, surfaceT85°C
Temperature, surfaceT100°C
Temperature, surfaceT130°C
Temperature, surfaceT135°C
Special conditionsyes (X), observe Ex manual
Equipment protection levelDc (Zone 22)

安全防爆 Safety Atex

×