| Advanced data for product |
| Nominal voltage |
| Specific value | 24 VDC |
| Limit values, min/max | 11/27 VDC |
| Nominal current, typically |
| Specific value | 20 mA |
| Condition | unloaded |
| Supply |
| Optional | 5 VDC ± 10 % |
| Device design |
| Type | Single-Turn |
| Total resolution | <= 12 Bit |
| Number of steps per revolution | <= 4096 |
| Number of revolutions | 1 |
| Accuracy | ± 0,7 ° |
| SSI - Interface |
| SSI-Clock input | Optocoupler |
| SSI-Data output | RS-485, 2-wire |
| SSI-Clock frequency | 80…1000 kHz |
| SSI-Mono time, typically | 20 µs |
| Parameter/Function, changeable | Resolution |
| | Output code |
| | Number of data bits |
| | Adjustment - Parameter |
| | SSI-Output |
| | Counting direction |
| Type of parametrization | programmable |
| Programming - Tool | TR-Soft: TRWinProg |
| External inputs |
| F/R | Count direction |
| Preset | electronic adjustment |
| Logic level | "0“ < +2V, "1“ = Supply |
| Circular runout | 0.2 mm |
| Mass, typically | 0.15 kg |
| General environmental conditions |
| Vibration |
| Specific value | <= 100 m/s² |
| Sine | 50…2000 Hz |
| Shock |
| Specific value | <= 1000 m/s² |
| Half sine | 11 ms |
| Immunity to disturbance | DIN EN 61000-6-2 |
| Transient emissions | DIN EN 61000-6-3 |
| Working temperature |
| Standard | -25…+70 °C |
| Storage temperature, dry | -20…+85 °C |
| Relative humidity | 98 % |
| Protection class |
| Standard | IP65 |
| Optional | IP69K |